Updated RFXmngr and new firmware version 1011

January 6th, 2017

Firmware changes in versions 433_1011
– MCZ pellet stove 3 fan model added

RFXmngr program version 18.0.0.13
– MCZ 3 fans selection added

Updated RFXmngr and new firmware version 1010

January 6th, 2017

Firmware changes in versions 433_1010
– Marquant 934134 added in Type2
– ARC undecoded updated

RFXmngr program version 18.0.0.11
– BlindsT3 unit number decoded
– MCZ 1 or 2 fans selection added
– Lighting4 added for RFXtrx315

RFXmngr program version 18.0.0.12
– special MCZ receiver (434.50MHz) added

Updated RFXmngr and new firmware version 1009

January 6th, 2017

Firmware changes in versions 433_1009
– RFY corrected

RFXmngr program version 18.0.0.10
– MCZ fan2 selection 0 added for 1 fan models

Updated RFXmngr and new firmware version 1008

October 27th, 2016

Firmware changes in versions 433_1008
– Mertik G6R-H4TD (DRU) receive corrected
– SA33 smoke detector added (Type1, Ext)
– MCZ pellet stove added (Type2, Ext)

RFXmngr program version 18.0.0.9
– Thermostat tabs renamed to Tstat
– Mertik ID’s corrected
– Tstat4 – MCZ pellet stove added

Updated RFXmngr and new firmware version 1007

October 9th, 2016

Firmware changes in versions 433_1007
– Firmware code optimized
– Lighting4 low pulse timing accepted
– WS1700 battery empty indication removed
– THN129 added
– Philips SBC unit 9-16 updated
– RM174RF smoke detector added (Ext2 firmware)
– Westinghouse fan control 7226640 added (Ext2 firmware)
– TFA 30.3056 and 30.3216 pool sensor added

RFXmngr program version 18.0.0.8
– Lighting1 – Philips SBC unit 1 – 16
– RM174RF smoke detector added
– Westinghouse fan added
– TFA 30.3056 pool sensor added
– ID displayed in hex and decimal

Updated RFXmngr and new firmware version 1006

August 9th, 2016

Firmware changes in versions 433_1006
– Motorlux added
– Seav TXS4 added
– Livolo updated
– WS3500/4500 rain sensor corrected

RFXmngr program
– FAN ID2 corrected
– FAN – SEAV added

Updated firmware versions 1004 & 1005

May 24th, 2016

Maintenance release with updates for AC, Livolo, LightwaveRF and RAEX.

Updated RFXmngr and new firmware version 1003

May 24th, 2016

Firmware changes in versions 433_1003
– Cartelectronic added to Type2 firmware
– Rubicson/IW008T/TX95 corrected
– WS3500/WS4500 temperature corrected
– MDRemote V108 added

RFXmngr program
– MDRemote V108 added

Updated RFXmngr and new firmware version 1002

May 6th, 2016

Firmware changes in versions 433_1002
– Cartelectronic TIC & Encoder added
– BlindsT6 updated
– ByronSX + Oregon enabled improved
– Somfy improved
– Mertik G6R-H4T1 improved
– WS1200 improved

RFXmngr program
– Transmit Confexx correct decoded
– Cartelectronic TIC/Encoder added
– Envivo transmit correct decoded
– RFY channel corrected
– Livolo dim and scene commands added

Updated RFXmngr and new firmware version 1001

March 9th, 2016

Firmware changes in versions 433_1001
– Firmware type Ext2 released
– Firmware version numbering is changed
– Firmware Type displayed in response message
– IT protocol PROmax, FA500S, FA500WD, FA500DSS added (Ext2)
– Auriol Z31055B-TX sensor added (Ext2)
– WS1200 battery low indicator added
– Chuango, Eminent security sensors added:
–    decoded as Lighting4 in Type1, Type2 and Ext
–    decoded as X10 in Ext2
– Confexx blind motor added (Ext2)

RFXmngr program
– Confexx blind motor added
– Lighting5 – IT protocol added
– Firmware type displayed