December 24, 2015

Updated RFXmngr and new firmware version 94, 194 and 250

Filed under: Firmware — RFXCOM @ 1:10 pm

New firmware released for the RFXtrx433 and RFXtrx433E
Please read chapter 2 of the RFXtrx User Guide.pdf to see which firmware type supports the protocols you need.The preferred firmware version for the RFXtrx433E is the Ext firmware.
The preferred firmware version for the RFXtrx433 is the Type1 or Type2 firmware.
Type1 or Type2 firmware can be flashed in the RFXtrx433 and the RFXtrx433E.

Firmware changes in versions 433_94/194/250
– Lucci Air fan added (Ext)
– Inovalley S80 plant humidity sensor added  (Ext)
– Rubicson pool sensor 48.019 added (Ext)
– ARC improved with RSL enabled (Type1)
– Blyss transmit improved

RFXmngr program
– TCP/IP support added
– Lucci Air fan added
– Inovalley S80 plant humidity sensor added

November 23, 2015

Updated RFXmngr and new firmware version 93, 193 and 249

Filed under: Firmware — RFXCOM @ 12:23 pm

New firmware released for the RFXrec433, RFXtrx433 and RFXtrx433E
Please read chapter 2 of the RFXtrx User Guide.pdf to see which firmware type supports the protocols you need.The preferred firmware version for the RFXtrx433E is the Ext firmware.
The preferred firmware version for the RFXtrx433 is the Type1 or Type2 firmware.
Type1 or Type2 firmware can be flashed in the RFXtrx433 and the RFXtrx433E.

Firmware changes in versions 433_93/193/249
– Mertik G6R-H4T16 added
– MDremote version 107 added
– Legrand CAD radio added (Ext only)
– Conrad RSL sensors improved (Type2 only)
– UPM improved (Type1 only)
– Cresta receive improved

RFXmngr program
– Legrand CAD added
– MDremote version 107 added
– Group code H corrected for Lighting6
– RSSI also displayed in dBi

September 17, 2015

Updated RFXmngr and new firmware version 92, 192 and 248

Filed under: Firmware — RFXCOM @ 1:35 pm

New firmware released for the RFXtrx433 and RFXtrx433E
Please read chapter 2 of the RFXtrx User Guide.pdf to see which firmware type supports the protocols you need.The preferred firmware version for the RFXtrx433E is the Ext firmware.
Firmware version for the RFXtrx433 is the Type1 or Type2 firmware.
Type1 or Type2 firmware can be flashed in the RFXtrx433 and the RFXtrx433E.

Firmware changes in versions 433_92/192/248
– Support for Home Confort added (only Ext firmware 248 for RFXtrx433E)
– Lighting4 improved

RFXmngr program
– Support for Home Confort added

August 31, 2015

Updated RFXmngr and new firmware version 247

Filed under: Firmware — RFXCOM @ 6:25 pm

New firmware released for the RFXtrx433E
Please read chapter 2 of the RFXtrx User Guide.pdf to see which firmware type supports the protocols you need.The preferred firmware version for the RFXtrx433E is the Ext firmware.
The preferred firmware version for the RFXtrx433 is the Type1 or Type2 firmware.
Type1 or Type2 firmware can be flashed in the RFXtrx433 and the RFXtrx433E.

Firmware changes in versions 433_247
– support for ASA ETR blind motors added

RFXmngr program
– support for ASA blind motors added

August 7, 2015

New firmware version 246

Filed under: Firmware — RFXCOM @ 12:44 pm

New firmware released for the RFXtrx433E
Please read chapter 2 of the RFXtrx User Guide.pdf to see which firmware type supports the protocols you need.
The preferred firmware version for the RFXtrx433E is the Ext firmware.
The firmware version for the RFXtrx433 is Type1 or Type2 firmware.
Type1 or Type2 firmware can be flashed in the RFXtrx433 and the RFXtrx433E.

Firmware changes in versions 433_246
– Oregon MSR939 motion sensor updated, false packets eliminated (Ext only)
– Revolt removed from Ext  (only available in Type2)

July 24, 2015

New firmware version 91, 191 and 245

Filed under: Firmware — RFXCOM @ 7:48 am

New firmware released for the RFXtrx433 and RFXtrx433E
Please read chapter 2 of the RFXtrx User Guide.pdf to see which firmware type supports the protocols you need.
The preferred firmware version for the RFXtrx433E is the Ext firmware.
The firmware version for the RFXtrx433 is Type1 or Type2 firmware.
Type1 or Type2 firmware can be flashed in the RFXtrx433 and the RFXtrx433E.

Firmware changes in versions 433_91/191/245
– Conrad RSL updated for sensors (Type2 only)
– Oregon MSR939 motion sensor added (Ext only)
– WS1700 updated for Banggood sensors (Ext only)
– BlindsT6 also in Ext available
– BlindsT6 Brel and ESMO blind motors added

June 23, 2015

New firmware version 90, 190 and 244

Filed under: Firmware — RFXCOM @ 3:40 pm

New firmware released for the RFXtrx433 and RFXtrx433E
Please read chapter 2 of the RFXtrx User Guide.pdf to see which firmware type supports the protocols you need.
The preferred firmware version for the RFXtrx433E is the Ext firmware.
The firmware version for the RFXtrx433 is Type1 or Type2 firmware.
Type1 or Type2 firmware can be flashed in the RFXtrx433 and the RFXtrx433E.

Firmware changes in versions 433_90/190/244
– Lighting4 reports the correct pulse length
– Imagintronix/XT300 optimized

June 7, 2015

Updated RFXmngr and new firmware version 89, 189 and 243

Filed under: Firmware — RFXCOM @ 8:42 am

New firmware released for the RFXtrx433 and RFXtrx433E
Please read chapter 2 of the RFXtrx User Guide.pdf to see which firmware type supports the protocols you need.The preferred firmware version for the RFXtrx433E is the Ext firmware.
The preferred firmware version for the RFXtrx433 is the Type1 or Type2 firmware.
Type1 or Type2 firmware can be flashed in the RFXtrx433 and the RFXtrx433E.

Firmware changes in versions 433_89/189/243
– RFY updated for Somfy DC RTS Receiver Part Number 1870135
– Alecto WS1700/WS4500 corrected
– Transmitter output level reported (+10dBm)
– RGB 432W added http://www.ebay.com/itm/191481664563 (maybe dx.com 227892??)

RFXmngr program
– The RFXmngr program is updated to support the new firmware.
– RGB432W added

May 5, 2015

Multiple weather sensors

Filed under: Using — RFXCOM @ 12:29 pm

Communication Failures will sometimes arise if you have 2 or more weather sensors of the same type and with the same channel selected. One or two sensors are sometimes not received for a few hours. The reason is that they transmit during this period on the same moment. The interval time differs a very little bit for each sensor and the transmit period shifts slowly and at a certain time both sensors transmit on a different time again and are received again.

The solution is to select another channel on each sensor of the same type or use different sensor types.
Note: TEMP1, TEMP2 are different types but THR128 and THC138 are the same types as they are both TEMP1 sensors!
The THGR810 is a 10 channel sensor and you can use 10 of these sensors without having the Communication Failure due to sensor transmission overlap.
If different channels are selected or different types are used and communication failures occur an out of range is the most expected problem. Don’t install the sensors near metal objects because this can limit the range too.

It can still happen that sensors transmit at the same time when having different sensor types or different channels selected but not for a long period and Communication Failures will not appear due to this.

For the list of supported weather sensor types see: http://www.rfxcom.com/oregon

May 2, 2015

Updated RFXmngr and new firmware version 87, 187 and 241

Filed under: Firmware — RFXCOM @ 9:04 am

New firmware released for the RFXtrx433 and RFXtrx433E
Please read chapter 2 of the RFXtrx User Guide.pdf to see which firmware type supports the protocols you need.The preferred firmware version for the RFXtrx433E is the Ext firmware.
The preferred firmware version for the RFXtrx433 is the Type1 or Type2 firmware.
Type1 or Type2 firmware can be flashed in the RFXtrx433 and the RFXtrx433E.

Firmware changes in versions 433_87/187/241
– KD101 number of xmit packets increased
– Mertik G6R_H4S added (transmit only)
– Improved; WS1700/WS4500
– Corrected Type2 firmware; Imagintronix/Opus with HW version 0
– Corrected; WT0122 temperatures < 14C
– Corrected; Transceiver type could be wrong after flash update

RFXmngr program
– The RFXmngr program is updated to support the new firmware.
– RFXSensor A/D and voltage corrected
– connect problem solved if another old FTDI device is connected to the system